Skip to content
Snippets Groups Projects
  1. Nov 05, 2007
    • Michael Hanselmann's avatar
      Rename utils.GetUUID to utils.NewUUID. · 24818e8f
      Michael Hanselmann authored
      Reviewed-by: schreiberal
      24818e8f
    • Guido Trotter's avatar
      Bump protocol version up · 8ee53a06
      Guido Trotter authored
      The OS cleanup patches change the wire protocol. Increment the protocol number
      by one.
      
      Reviewed-By: iustinp
      
      8ee53a06
    • Guido Trotter's avatar
      Convert os_get to use OS rather than InvalidOS · dfa96ded
      Guido Trotter authored
      In order to do this for simplicity we leave the OSFromDisk function as-is and
      we convert the eventual exception to an OS object in ganeti-noded. The
      unmangling gets simplified and so does the code for checking whether the OS is
      valid.
      
      Reviewed-By: iustinp
      
      dfa96ded
    • Guido Trotter's avatar
      Simplify diagnose mangling/unmangling functions · 4e679f11
      Guido Trotter authored
      The functions in ganeti-noded and rpc.py still deal with the fact that an
      InvalidOS error could be returned by DiagnoseOS. As this is not the case
      anymore simplify their code for the current behavior.
      
      Reviewed-By: iustinp
      
      4e679f11
    • Guido Trotter's avatar
      Make DiagnoseOS use the modified OS objects · 8fa42c7c
      Guido Trotter authored
      Modify backend.py so that DiagnoseOS only returns OS objects rather than
      InvalidOS errors, and make sure gnt-os understands the new objects. Also delete
      the deprecated helper functions from gnt-os.
      
      Reviewed-By: iustinp
      
      8fa42c7c
    • Guido Trotter's avatar
      Create OS from an InvalidOS error · d2c807e4
      Guido Trotter authored
      Add a new FromInvalidOS static function to objects.OS that makes it easy to
      create an object representing a broken OS starting from the relevant exception.
      
      Reviewed-By: iustinp
      
      d2c807e4
    • Guido Trotter's avatar
      Make the OS object able to represent broken OSes · 37482e7b
      Guido Trotter authored
      Till now the OS object just represents a correct OS instance.  Change it so it
      can represent a broken one too, by adding a "status" field: if this field is
      different from the OS_VALID_STATUS constant the object is considered to be an
      invalid OS, the "status" field to be a debugging message, and its boolean
      status is set to false.
      
      Reviewed-By: iustinp
      37482e7b
  2. Nov 04, 2007
  3. Nov 03, 2007
    • Iustin Pop's avatar
      Implement tag searching · 73415719
      Iustin Pop authored
      This patch adds a search command for locating tags on all objects of the
      cluster using a regex pattern.
      
      Reviewed-by: aat
      73415719
  4. Nov 02, 2007
    • Michael Hanselmann's avatar
      Test “gnt-cluster command”. · 830da270
      Michael Hanselmann authored
      Also check whether file contents are correct for both “gnt-cluster command” and
      “gnt-cluster copyfile”.
      
      Reviewed-by: iustinp
      
      830da270
    • Iustin Pop's avatar
      Implement device to instance mapping cache · 3f78eef2
      Iustin Pop authored
      Currently, troubleshooting DRBD problems involves a manual process of going
      backwards from the DRBD device to the instance that owns it.
      
      This patch adds a weak (i.e. not guaranteed to be correct or up-to-date)
      cache of device to instance. The cache should be, in normal operation,
      having correct information as the only time when devices change paths
      are when they are started/stopped, and the code in backend.py adds cache
      updates to exactly these operations.
      
      The only drawback of this implementation is that we don't fully update
      the cache on renames of devices (we clean the old entries but we don't
      add new ones). Since the rename changes the path only for LVs (and not
      drbd and md), this is less of a problem as the target of this code is
      debugging DRBD and MD issues.
      
      The patch writes files named bdev_drbd<N> (or bdev_md<N>,
      bdev_xenvg_...) in /var/run/ganeti (more exactly, LOCALSTATEDIR/ganeti).
      The files start with 'bdev_' and continue with the path of the device
      under /dev/ (this prefix stripped), and contain the following values,
      space separated:
        - instance name
        - primary or secondary (depending on how the device is on the primary
          or secondary node)
        - instance visible name: sda or sdb or not_visible, the latter case
          when the device is not the top-level device (i.e. remote_raid1
          templates will have sd[ab] for the md, but not_visible for drbd and
          logical volumes)
      
      The cache is designed to not raise any errors, if there is an I/O error
      it will only be logged in the node daemon log file. This is in order to
      reduce the possible impact of the cache on the block device activation
      and shutdown code.
      
      Reviewed-by: imsnah
      3f78eef2
    • Iustin Pop's avatar
      Improve burnin with regard to drbd8 · 79f87a76
      Iustin Pop authored
      Allow burnin to use the new drbd8 template (for which case one needs to
      disable replacement of disks, burnin does yet support that with drbd8).
      
      The patch also changes do-replace[12] to no-replace[12] as that is what
      they actually do.
      
      Reviewed-by: imsnah
      79f87a76
    • Iustin Pop's avatar
      Update the dev_path on LVs on rename · be345db0
      Iustin Pop authored
      When renaming a logical volume, we should change the dev_path (and other
      internal variables) in order to be consistent.
      
      Reviewed-by: imsnah
      be345db0
    • Iustin Pop's avatar
      Revision 302 is broken, this fixes it · 25a915d0
      Iustin Pop authored
      I forgot a pair of parentheses in that revision which break the common
      case. This patch adds them.
      
      Reviewed-by: ultrotter
      25a915d0
  5. Nov 01, 2007
    • Iustin Pop's avatar
      Fix printing of unconfigured DRBD devices · 073ca59e
      Iustin Pop authored
      If the device is unconfigured (not yet did SetDiskID for it ever), it
      might have a physical_id of None. This patch fixes that case.
      
      Reviewed-by: ultrotter
      073ca59e
    • Guido Trotter's avatar
      Remove two trailing whitespaces · d06565e0
      Guido Trotter authored
      Ok, I've been battling with those for a while but it seems
      in the end I forgot to get rid of them! :( Doing it explicitely now.
      
      Reviewed-By: iustinp
      d06565e0
    • Guido Trotter's avatar
      Move blank lines inside function messages · 2527691a
      Guido Trotter authored
      This patch changes whitespace only. It fixes all the functions in script/gnt-os
      by putting a white line at the end of all the function descriptions and
      removing it from just before the code.
      
      Reviewed-By: iustinp
      2527691a
    • Guido Trotter's avatar
      Add empty line after each diagnose OS-Node set · dd96409a
      Guido Trotter authored
      Reviewed-By: imsnah
      dd96409a
    • Guido Trotter's avatar
      Modify the displayed format for gnt-os diagnose · 107b0ccb
      Guido Trotter authored
      Get rid of the tabulated form and create a simplier indented structure.
      Now a valid OS looks something like:
      
      OS: foo [global status: partial valid]
        Node: gsdtest4.euw.corp.google.com, status: valid (path: /usr/local/lib/ganeti/os/foo)
        Node: gsdtest5.euw.corp.google.com, status: valid (path: /usr/local/lib/ganeti/os/foo)
          [hidden] path: /usr/local/lib/ganeti/os2/foo, status: 'ganeti_api_version' file not found (ENOENT)
        Node: gsdtest3.euw.corp.google.com, status: 'ganeti_api_version' file not found (ENOENT) (path: /usr/local/lib/ganeti/os/foo)
      
      Reviewed-By: imsnah
      107b0ccb
    • Guido Trotter's avatar
      Change the way to compute the first os status message · 48f85f75
      Guido Trotter authored
      Use both _DiagnoseOSStatus and  _DiagnoseOSPath to calculate the message
      associated with the first entry found on a node for an OS. Also call the rename
      the relevant variables to _msg rather than just _status to reflect that they
      contain a bit more than just the bare status message.
      
      Reviewed-By: imsnah
      
      48f85f75
    • Guido Trotter's avatar
      Separate OS status and path · 5efc50fc
      Guido Trotter authored
      Make _DiagnoseOSStatus only return a status message for the OS diagnose object
      and create a new _DiagnoseOSPath function to get the path out. This will let us
      be more flexible in the messages we display to the user.
      
      Reviewed-By: imsnah
      5efc50fc
    • Iustin Pop's avatar
      Whitespace fixes · 5d0fe286
      Iustin Pop authored
      Reviewed-by: ultrotter
      5d0fe286
    • Michael Hanselmann's avatar
      Cleanup colouring functions. · dfe11bad
      Michael Hanselmann authored
      Make the code somewhat smaller. Disable disk failure test for master for now.
      
      Reviewed-by: schreiberal
      
      dfe11bad
    • Michael Hanselmann's avatar
      Cleanup QA scripts. · b1ffe1eb
      Michael Hanselmann authored
      - Split main() function into several small ones.
      - Current work on disk failure tests. This is not yet finished.
      - Fix small typo in qa_node.py.
      
      Reviewed-by: schreiberal
      
      b1ffe1eb
  6. Oct 31, 2007
    • Iustin Pop's avatar
      Revert "Implement multi-failover options" · 80de0e3f
      Iustin Pop authored
      This reverts commit 289, as the node failover functionality was already
      implemented in gnt-node (as opposed to gnt-instance). My mistake.
      
      Reviewed-by: ultrotter
      80de0e3f
    • Michael Hanselmann's avatar
      Fix usage of OpReplaceDisks. · 22d31e49
      Michael Hanselmann authored
      Reviewed-by: iustinp
      
      22d31e49
    • Iustin Pop's avatar
      Small improvements to multi-instance selections · bcee9cb4
      Iustin Pop authored
      This patch fixes the documentation in a few cases and adds handling of
      the situation where no instance is selected due to too restrictive
      options given.
      
      Reviewed-by: imsnah
      bcee9cb4
    • Iustin Pop's avatar
      Implement multi-failover options · 36c87212
      Iustin Pop authored
      This patch adds the same style of multi-instance selection as in
      shutdown/startup to the failover subcommand, with the exception that we
      cannot failover with --node or --all (it doesn't make sense).
      
      Reviewed-by: imsnah
      36c87212
    • Iustin Pop's avatar
      More sane handling of errors during failover · 24a40d57
      Iustin Pop authored
      Currently we ignore errors on instance shutdown (on the source node)
      during instance failover. We should do this only if the user gave a
      command line options allowing this, as it's a dangerous thing to do.
      
      This patch fixes this by using the same "--ignore-consistency" option
      for deciding whether to continue or abort. It also expands a bit the man
      page.
      
      Reviewed-by: imsnah
      24a40d57
    • Iustin Pop's avatar
      Fix bridge checking in instance failover · 50ff9a7a
      Iustin Pop authored
      The current code checks the bridge on the primary node of the instance,
      but we need to check it on the destination node.
      
      This was caught by testing failover with a down primary node.
      
      Reviewed-by: imsnah
      50ff9a7a
  7. Oct 30, 2007
  8. Oct 29, 2007
Loading