- Sep 05, 2012
-
-
Dimitris Aragriorgs authored
This is only needed in case base64 and bitarray.tostring() is used for saving reservations. If bitarray.to01() was used then we would not have this restriction. Signed-off-by:
Dimitris Aragriorgs <dimara@grnet.gr>
-
- Aug 31, 2012
-
-
Dimitris Aragriorgs authored
Signed-off-by:
Dimitris Aragriorgs <dimara@grnet.gr>
-
- Aug 30, 2012
-
-
Dimitris Aragriorgs authored
Signed-off-by:
Dimitris Aragriorgs <dimara@grnet.gr>
-
Dimitris Aragriorgs authored
Introduce _GenerateKVMBlockDevicesOptions() In case hotplug is enabled per instance then the runtime file contains one more field: block_devices. In this case kvm_cmd is extended with block device options during _ExecuteKVMRuntime(). If no hotplug is enabled then runtime file has block_devices info encapsulated in kvm_cmd and block device options are exteded during _GenerateKVMRuntime. Signed-off-by:
Dimitris Aragriorgs <dimara@grnet.gr>
-
- Aug 22, 2012
-
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Conflicts: Makefile.am lib/cli.py lib/client/gnt_instance.py lib/cmdlib.py lib/constants.py lib/opcodes.py Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Constantinos Venetsanopoulos authored
* ganeti-extstorage-interface man page * gnt-storage man page Signed-off-by:
Constantinos Venetsanopoulos <cven@grnet.gr>
-
Constantinos Venetsanopoulos authored
-
Constantinos Venetsanopoulos authored
Add a new client called 'gnt-storage'. The client interacts with the ExtStorage interface, similarly to the way gnt-os interacts with the OS interface. For now, only two commands are supported: 'info' and 'diagnose'. 'diagnose' calculates the node status of each provider on each node, similarly to gnt-os diagnose. Furthermore, for every provider, it calculates it's nodegroup validity for each nodegroup. This is done inside the LU and not the client (marked as 'TODO' for the global validity of gnt-os diagnose). In the future, gnt-storage can be used to manage storage pools, or even be extended to diagnose other storage types supported by Ganeti, such as lvm, drbd (INT_MIRROR) or rbd (EXT_MIRROR). Signed-off-by:
Constantinos Venetsanopoulos <cven@grnet.gr>
-
Constantinos Venetsanopoulos authored
Signed-off-by:
Constantinos Venetsanopoulos <cven@grnet.gr>
-
Constantinos Venetsanopoulos authored
Add support for passing parameters to the ext template (ext-params). Take advantage of disk-params, that don't seem to make much sense in this template (ExtStorage Providers are not predefined and we don't know their needs) and use them to pass the ext-params dynamically to the template. ext-params are correlated with gnt-os-interface's os-params. All ext-params are exported to the ExtStorage Provider through it's environment, with variables prefixed with 'EXTP_' (similarly to the OS interface's 'OSP_' params). ext-params are passed through the --disk option. If the disk template is of type `ext' during instance add, then any additional options that are not in IDISK_PARAMS given to --disk are considered ext-params e.g.: gnt-instance add -t ext --disk=0:size=2G,param1=value1,param2=value2 Finally, we introduce a new IDISK_PARAM called IDISK_PROVIDER, that is mandatory for template `ext' and is used to select the desired ExtStorage Provider. This parameter is not valid for other template types. The IDISK_PROVIDER parameter becomes the first element of the disk's unique_id tuple e.g.: unique_id = ('sample_provider1', 'UUID.ext.diskX') Example selecting different ExtStorage Providers for each disk and passing different ext-params to them: -t ext --disk=0:size=2G,provider=sample_provider1,param1=value1 --disk=1:size=3G,provider=sample_provider2,param2=value2 Signed-off-by:
Constantinos Venetsanopoulos <cven@grnet.gr>
-
Constantinos Venetsanopoulos authored
With this commit we introduce the External Storage Interface to Ganeti, abbreviated: ExtStorage Interface. The ExtStorage Interface provides Ganeti with the ability to interact with externally connected shared storage pools, visible by all VM-capable nodes. This means that Ganeti is able to handle VM disks that reside inside a NAS/SAN or any distributed block storage provider. The ExtStorage Interface provides a clear API, heavily inspired by the gnt-os-interface API, that can be used by storage vendors or sysadmins to write simple ExtStorage Providers (correlated to gnt-os-interface's OS Definitions). Those Providers will glue externally attached shared storage with Ganeti, without the need of preprovisioned block devices on Ganeti VM-capable nodes as confined be the current `blockdev' disk template. To do so, we implement a new disk template called `ext' (of type DTS_EXT_MIRROR) that passes control to externally provided scripts (the ExtStorage Provider) for the template's basic functions: create / attach / detach / remove / grow The scripts reside under ES_SEARCH_PATH (correlated to OS_SEARCH_PATH) and only one ExtStorage Provider is supported called `ext'. The disk's logical id is the tuple ('ext', UUID.ext.diskX), where UUID is generated as in disk template `plain' and X is the disk's index. Signed-off-by:
Constantinos Venetsanopoulos <cven@grnet.gr>
-
Constantinos Venetsanopoulos authored
Update the shared storage design document to reflect the current changes, after the implementation of the ExtStorage interface. Signed-off-by:
Constantinos Venetsanopoulos <cven@grnet.gr>
-
Dimitris Aragiorgis authored
Conflicts: lib/cli.py lib/client/gnt_instance.py lib/cmdlib.py lib/objects.py lib/opcodes.py lib/rpc.py Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Add --hotplug option. Only used by OpInstanceCreate()/OpInstanceSetParams. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Hotplugging is done by functions invoked by ApplyContainerMods(). In order hotplugging to take place a --hotplug option must be passed. Hotplug can enabled for a VM if --hotplug is passed during gnt-instance add (hotplug_info will be added). In order initial devices of a VM to be hotpluggable hotplug_info must be early available. So _GetPCIInfo() gets either lu.hotplug_info in case of LUInstanceCreate() or invokes lu.cfg.GetPCIInfo() in case of LUInstanceSetParams(). To return a pci slot into the pool lu.cfg.UpdatePCIInfo() must be invoked. If no --hotplug is passed during gnt-instance modify --net add the nic won't get a pci value and will be placed automaticaly in a free pci slot after reboot. This means that is not going to be hotpluggable for the rest of the instance's life. To keep pci pool consistent we do not let a device that has been hotplugged (i.e. has pci value) to be removed without --hotplug. Before hotplugging a Disk it must be assembled. During LuInstanceSetParams() newly created disks are not added to the instance so _ExpandCheckDisks() in _AssembleInstanceDisks() will fail. So we make this check optional only for this case. In order to remove a disk (with blockdev_remove) it must be shutdown. So after unplugging the disk _ShutdownDiskInstanceDisks() must be invoked. Everything else is just like nic hotplugging. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Introduce new RPCs that eventually invoke hypervisor specific hotplug functions. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
KVM >= 1.0 is needed. Introduce new methods: HotAddNic/HotDelNic Both qemu monitor interface for hotplugging. If a device has hotplug info (idx, pci) then: - it gets named after it (e.g. virtio-net-pci.%d % idx ). - it gets placed to the pci slot (hex(pci)) of bus 0. If no hotplug info exist or kvm version is old then no hotplug takes place and modifications will take place after reboot: - devices will get traditionaly named - and placed automaticaly in empty pci slots NIC hotplug: - open a tap and get its file descriptor. - pass fd with SCM rights (using python-fdsend) via monitor socket - create netdev and device with proper qemu interface Disk hotplug: - create drive with drive%d % idx name - create device virtio-blk-pci.%d % idx In order to migrate a VM that has devices hotplugged, an identical VM should be booted with -incoming. To this end every time a hotplug takes place runtime file must be updated. For disk hotplug support we removeds disk from kvm_cmd in runtime file add added them separately just like nics. So code building disk related options has been moved out from _GenerateKVMRuntime() and added to _ExecuteKVMRuntime(). Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Introduce new HotplugInfo object as part of Instance object. hotplug_info { 'nics': 0, 'disks': 0, 'pci_pool': [16, 17, 18] } nics/disks is an index used for device identification and naming. Everytime a new device (disk/nic) is hotadded these values get incremented. pci_pool is a list of pci slots where a device can be placed. Every time a device gets hot-plugged/unplugged a pci slot gets popped/appended. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Support: - gnt-network add --tags. - gnt-network list-tags/add-tags/remove-tags/. - gnt-network list -o +tags Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
If a nic has a network field then encapsulate a network object in netinfo slot for every rpc. This is needed to pass network info to scripts managing nics (kvm-vif-bridge). Introduce _BuildNetworkEnv() Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Add networks slot in config data. Add networks slot in nodegroups. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Modify existing GenerateMAC so that it takes network as an argument. Substitute _GenerateOneMAC with a decorator _GenerateMACPrefix that chooses the prefix (network's or cluster's) and wraps _GenerateMACSuffix that generates the three remaining bytes. Check mac prefix validity when adding/modifing a network. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Support: - GetNetwork(s) - CreateNetwork - ConnectNetwork - DisconnectNetwork - RemoveNetwork Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
gnt-network is used to manipulate and handle networks that currently provides the following operations: * Add a new network: gnt-network add --network=1.2.3.0/28 --gateway=1.2.3.1 --add-reserved-ips=1.2.3.4,1.2.3.5 testnet * Remove an existing network: gnt-network remove testnet * Modify an existing network: gnt-network modify --gateway=1.2.3.6 --network-type=private --network6=2001:648::/64 --gateway6=none testnet --add-reserved-ips=1.2.3.10,1.2.3.10, --remove-reserved-ips=1.2.3.20 testnet * Connect an existing network to a nodegroup: gnt-network connect testnet default bridged br100 gnt-network connect testnet <nodegroup> <mode> <link> (pass all for <nodegroup> to connect to all nodegroups) * Disconnect an existing network from a nodegroup: gnt-network disconnect testnet <nodegroup> (pass all for <nodegroup> to disconnect from all nodegroups) * List available networks: gnt-network list * Show network info: gnt-network info [testnet] Introduce new option NOCONFLICTSCHECK_OPT for not checking for conflicting IPs. Using this might cause data inconsistency. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Add --no-conflicts-check option. Modify instance query methods to return nic's network info. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Specifically: * export a new environment variable for the gnt-os-interface * export a new environment variable for KVM specific scripts * ovf support for networks Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Keep backwards compatibility just like LUInstanceCreate() and support network parameter for NIC object. Add ec_id argument in Update() to be able to commit temporary IPs that were previously reserved. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Release any IPs held the instance before actually removing. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Implement backend support, to export the IP pool management functionality to the clients. When the new NIC parameter 'network' is given, the ippool management system is triggered. If a NIC belongs to a network, it inherits the netparams (mode, link) as its nicparams. If a network is requested, then no 'mode' or 'link' should be specified. Backwards compatibility is preserved, if 'network' parameter is omitted. Examples for IP pool management system: --net 0:network=net1 for an IPless NIC in a network --net 0:ip=pool,network=net1 for automatically generated IP inside the network --net 0:ip=1.2.3.4,network=net1 for specific IP inside the network --net 0:network=none for IPless NIC with default nicparams Examples for traditional assignment: --net 0:ip=1.2.3.4,link=br100,mode=bridged --net 0:ip=none,link=rt2,mode=routed --net 0 Check for conflicting IPs to ensure IP uniqueness inside nodegroups. IAllocator should be extended to become network aware. If an instance has a NIC inside a network, then IAllocator must pick a node that its nodegroup is already connected with that network. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Use TemporaryReservationManager for IP handling to ensure config data consistency. Implement: - methods for reserving/releasing IPs - _UnlockedCommitTemporaryIps() - CheckIPInNodeGroup() used for conflicting IPs - GetGroupNetParams() used for inheriting netparams. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
LUNetworkConnect() connects a network to a nodegroup and defines its netparams (mode and link). Specifically: * Check if network already exists * Check if netparams are valid * Check if already connected to the same nodegroup * Produce errors if any conflicting IPs found * Update the 'networks' slot in NodeGroup config object with the network UUID and netparams requested. E.g. nodegroup_uuid { networks { network_uuid: {mode: 'bridged', link: 'br100'} } } LUNetworkDisconnect() unmaps a network from a nodegroup: * Produce errors if an instance has a NIC with IP inside the network * Remove corresponding entry in 'networks' slot of NodeGroup object Check for conflicting ips can be avoided with corresponding option. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Support modifying all network parameters except for network (ip range) Cannot modify gateway and reserved ips at the same time. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-
Dimitris Aragiorgis authored
Summarily list all existing networks Supply detailed info for every existing network - List used/free IPs - List instances with NICs assigned to the corresponding network - List NIC index and IP for the above instances Implement complementary config methods for retrieving networks. Signed-off-by:
Dimitris Aragiorgis <dimara@grnet.gr>
-