Commit cfed3b9f authored by René Nussbaumer's avatar René Nussbaumer

gnt-cluster epo: Adding --power-delay flag

Signed-off-by: default avatarRené Nussbaumer <rn@google.com>
Reviewed-by: default avatarIustin Pop <iustin@google.com>
parent 0a1fc31c
......@@ -917,7 +917,8 @@ def _OobPower(opts, node_list, power):
op = opcodes.OpOobCommand(node_names=node_list,
command=command,
ignore_status=True,
timeout=opts.oob_timeout)
timeout=opts.oob_timeout,
power_delay=opts.power_delay)
result = SubmitOpCode(op, opts=opts)
errs = 0
for node_result in result:
......@@ -1314,7 +1315,7 @@ commands = {
"epo": (
Epo, [ArgUnknown()],
[FORCE_OPT, ON_OPT, GROUPS_OPT, ALL_OPT, OOB_TIMEOUT_OPT,
SHUTDOWN_TIMEOUT_OPT],
SHUTDOWN_TIMEOUT_OPT, POWER_DELAY_OPT],
"[opts...] [args]",
"Performs an emergency power-off on given args"),
}
......
......@@ -96,19 +96,23 @@ argument *--yes-do-it.*
EPO
~~~
**epo** [--on] [--groups|--all] *arguments*
Performs an emergency power-off on nodes given as arguments. If ``--groups``
is given, arguments are node groups. If ``--all`` is provided, the whole
cluster will be shut down.
The ``--on`` flag recovers the cluster after an emergency power-off
Please note that the master node will not be turned down or up automatically.
It will just be left in a state, where you can manully perform the shutdown of
that one node. If the master is in the list of affected nodes and this is not a
complete cluster emergency power-off (e.g. using ``--all``), you're required to
do a master failover to another node not affected.
**epo** [--on] [--groups|--all] [--power-delay] *arguments*
Performs an emergency power-off on nodes given as arguments. If
``--groups`` is given, arguments are node groups. If ``--all`` is
provided, the whole cluster will be shut down.
The ``--on`` flag recovers the cluster after an emergency power-off.
When powering on the cluster you can use ``--power-delay`` to define the
time in seconds (fractions allowed) waited between powering on
individual nodes.
Please note that the master node will not be turned down or up
automatically. It will just be left in a state, where you can manully
perform the shutdown of that one node. If the master is in the list of
affected nodes and this is not a complete cluster emergency power-off
(e.g. using ``--all``), you're required to do a master failover to
another node not affected.