1. 24 Apr, 2014 1 commit
  2. 21 Mar, 2014 1 commit
  3. 20 Jan, 2014 1 commit
  4. 17 Dec, 2013 1 commit
  5. 19 Nov, 2013 1 commit
  6. 14 Nov, 2013 2 commits
  7. 25 Sep, 2013 1 commit
  8. 06 Aug, 2013 1 commit
  9. 10 Jul, 2013 1 commit
  10. 01 Jul, 2013 1 commit
  11. 20 Jun, 2013 1 commit
    • Thomas Thrainer's avatar
      Index instances by their UUID · da4a52a3
      Thomas Thrainer authored
      
      
      No longer index instances by their name but by their UUID in the cluster
      config. This change changes large parts of the code, as the following
      adjustments were necessary:
       * Change the index key to UUID in the configuration and the
         ConfigWriter, including all methods.
       * External interfaces (command line interface, IAllocator interface,
         hook scripts, etc.) are kept stable.
       * Instance UUID's are resolved in ExpandNames and then stored in the
         OpCode. This allows to check for instance renames if the OpCode is
         reloaded after a cluster restart. This check is currently only done
         for single instance parameters.
       * Instance locking unfortunately can't use instances UUID as
         identifiers. The reasons is that new instances (which have no UUID
         yet) have to be locked as well, so the instance name is used.
       * Variable names are renamed to follow the following pattern:
         - Suffix is 'inst' or 'insts': Variable holds Instance objects
         - Suffix is 'name' or 'names': Variable holds Instance names
         - Suffix is 'uuid' or 'uuids': Variable holds Instance UUID's
       * Tests are adapted.
      Signed-off-by: default avatarThomas Thrainer <thomasth@google.com>
      Reviewed-by: default avatarKlaus Aehlig <aehlig@google.com>
      da4a52a3
  12. 14 Jun, 2013 1 commit
  13. 13 Jun, 2013 1 commit
    • Thomas Thrainer's avatar
      Index nodes by their UUID · 1c3231aa
      Thomas Thrainer authored
      
      
      No longer index nodes by their name but by their UUID in the cluster
      config. This change changes large parts of the code, as the following
      adjustments were necessary:
       * Change the index key to UUID in the configuration and the
         ConfigWriter, including all methods.
       * Change all cross-references to nodes to use UUID's.
       * External interfaces (command line interface, IAllocator interface,
         hook scripts, etc.) are kept stable.
       * RPC-calls can resolve UUID's as target node arguments, if the RPC
         runner is based on a ConfigWriter instance. The result dictionary is
         presented in the form the nodes are addressed: by UUID if UUID's were
         given, or by name if names were given.
       * Node UUID's are resolved in ExpandNames and then stored in the
         OpCode. This allows to check for node renames if the OpCode is
         reloaded after a cluster restart. This check is currently only done
         for single node parameters.
       * Variable names are renamed to follow the following pattern:
         - Suffix is 'node' or 'nodes': Variable holds Node objects
         - Suffix is 'name' or 'names': Variable holds node names
         - Suffix is 'uuid' or 'uuids': Variable holds node UUID's
       * Tests are adapted.
      Signed-off-by: default avatarThomas Thrainer <thomasth@google.com>
      Reviewed-by: default avatarKlaus Aehlig <aehlig@google.com>
      1c3231aa
  14. 07 Jun, 2013 1 commit
  15. 03 Jun, 2013 1 commit
  16. 28 May, 2013 1 commit
  17. 17 Apr, 2013 1 commit
  18. 12 Mar, 2013 2 commits
  19. 25 Feb, 2013 1 commit
  20. 18 Feb, 2013 1 commit
  21. 11 Feb, 2013 1 commit
  22. 22 Dec, 2012 1 commit
    • Constantinos Venetsanopoulos's avatar
      Add the gnt-storage client · b954f097
      Constantinos Venetsanopoulos authored
      
      
      Add a new client called 'gnt-storage'.
      The client interacts with the ExtStorage interface, similarly to
      the way gnt-os interacts with the OS interface.
      
      For now, only two commands are supported: 'info' and 'diagnose'.
      
      'diagnose' calculates the node status of each provider on each node,
      similarly to gnt-os diagnose. Furthermore, for every provider, it
      calculates it's nodegroup validity for each nodegroup. This is done
      inside the LU and not the client (marked as 'TODO' for the  global
      validity of gnt-os diagnose).
      
      In the future, gnt-storage can be used to manage storage pools,
      or even be extended to diagnose other storage types supported by
      Ganeti, such as lvm, drbd (INT_MIRROR) or rbd (EXT_MIRROR).
      Signed-off-by: default avatarConstantinos Venetsanopoulos <cven@grnet.gr>
      Signed-off-by: default avatarIustin Pop <iustin@google.com>
      [iustin@google.com: fixed Haskell compatibility and style fixes]
      Reviewed-by: default avatarIustin Pop <iustin@google.com>
      b954f097
  23. 21 Dec, 2012 1 commit
  24. 19 Dec, 2012 3 commits
  25. 27 Nov, 2012 2 commits
  26. 20 Nov, 2012 6 commits
  27. 11 Oct, 2012 2 commits
  28. 03 Sep, 2012 2 commits